Description
1. Core Scanning & Probe Parameters
This section covers the core hardware configurations that determine scanning performance, ensuring stable and precise imaging for clinical needs:
-
Scan Mode: Electronic Array & Electronic Convex Array Scanning, enabling uniform acoustic beam transmission for consistent deep-tissue imaging.
-
Probe Specifications: Convex probe with dual-frequency adjustment (3.2MHz/5.0MHz) – 3.2MHz for deep-tissue penetration (e.g., abdominal organs), 5.0MHz for balanced resolution and penetration in medium-depth tissues.
-
Signal Processing: 80 high-precision elements, 64-channel signal transmission, ensuring accurate capture of weak ultrasound signals with minimal distortion.
-
Imaging Range: Adjustable scanning depth (90-200mm) to adapt to different tissue depths; Convex R60 field of view, providing a wide imaging scope for comprehensive observation of abdominal and pelvic structures.
2. Imaging Quality & Adjustment Functions
Key parameters and adjustable functions that optimize imaging clarity and detail recognition:
-
Image Foundation: 256-level gray scale, accurately reproducing subtle density differences between normal tissues and lesions for precise diagnosis.
-
Adjustment Tools: Gain (30dB-105dB) for brightness regulation; 5-level noise reduction (0-4) to filter interference; 8-level dynamic range (40-110) to enhance image layering.
-
Display Modes: B-mode (real-time 2D gray-scale imaging) and B/M-mode (combined 2D and time-axis imaging), suitable for static tissue observation and dynamic monitoring (e.g., fetal heart rate).
3. Compatibility & Data Management
System adaptability and data handling capabilities for convenient clinical application:
-
Device Compatibility: Supports smartphone/tablet screens; compatible with iOS, Android, and Windows systems for cross-terminal flexibility.
-
Data Storage: Images and videos directly stored in mobile devices/tablets, eliminating the need for additional storage equipment, facilitating on-site review and case sharing.
-
Measurement Functions: Built-in tools for distance, area, and obstetric parameters (e.g., fetal biparietal diameter), providing quantitative data support for diagnosis.
4. Power & Physical Specifications
Portability and power performance optimized for mobile clinical scenarios:
-
Power Supply: Built-in 4200mAh lithium battery, supporting 3 hours of continuous operation, fully covering daily examination needs.
-
Physical Dimensions: 156mm×60mm×20mm compact size, 250g net weight, ergonomic design for comfortable handheld operation and easy portability.
5. Standard & Optional Configurations
Comprehensive configuration options to meet basic and personalized needs:
-
Standard Configuration: 1×Wireless Probe Type Ultrasound Scanner, 1×USB Charging Cable.
-
Optional Accessories: Carrying Bag, Aluminium Suitcase (shockproof storage), Stainless Steel Puncture Guide (interventional assistance), Wireless Power Bank (extended battery life), pre-configured mobile devices, Tablet Bracket, and Trolley (mobile operation platform).
With balanced performance, portability, and functional flexibility, the VISION3 C convex probe ultrasound system provides reliable imaging solutions for diverse clinical scenarios, from routine clinics to mobile medical services.
Your message has been sent












Reviews
There are no reviews yet.